{ "culture": "en-US", "name": "", "guid": "", "catalogPath": "", "snippet": "The Facility Locations (Proposed) (EPM_FACILITY_PT) is the location of facilities that have been submitted to the BC Energy Regulator for review and approval.", "description": "
Facilities are an oil and gas activity, defined in the as a system of vessels, piping, valves, tanks and other equipment used to gather, process, measure, store or dispose of petroleum, natural gas, water or a substance referred to in paragraph (d) or (e) of the definition of pipeline. This dataset contains point features for proposed applications collected through the BC Energy Regulator's Application Management System (AMS) and are in the review phase.<\/SPAN><\/SPAN><\/P> Data Properties<\/SPAN><\/SPAN><\/P> Attributes / Column Name<\/SPAN><\/SPAN><\/P><\/TD> Field Alias<\/SPAN><\/SPAN><\/P><\/TD> Data Type<\/SPAN><\/SPAN><\/P><\/TD> Data Precision<\/SPAN><\/SPAN><\/P><\/TD> Comments<\/SPAN><\/SPAN><\/P><\/TD><\/TR> OBJECTID<\/SPAN><\/SPAN><\/P><\/TD> OBJECTID<\/SPAN><\/SPAN><\/P><\/TD> Object ID<\/SPAN><\/SPAN><\/P><\/TD> Unique row value assigned by database<\/SPAN><\/SPAN><\/P><\/TD><\/TR> SHAPE<\/SPAN><\/SPAN><\/P><\/TD> SHAPE<\/SPAN><\/SPAN><\/P><\/TD> Geometry<\/SPAN><\/SPAN> (Point)<\/SPAN><\/SPAN><\/P><\/TD> FACILITY_ID<\/SPAN><\/SPAN><\/P><\/TD> Facility ID<\/SPAN><\/SPAN><\/P><\/TD> Text<\/SPAN><\/SPAN><\/P><\/TD> 8<\/SPAN><\/SPAN><\/P><\/TD> Number assigned to each facility within an application<\/SPAN><\/SPAN><\/P><\/TD><\/TR> FACILITY_TYPE<\/SPAN><\/SPAN><\/P><\/TD> Facility Type<\/SPAN><\/SPAN><\/P><\/TD> Text<\/SPAN><\/SPAN><\/P><\/TD> 4<\/SPAN><\/SPAN><\/P><\/TD> Code indicating the type of facility, e.g., CD (Compressor Dehydrator)<\/SPAN><\/SPAN><\/P><\/TD><\/TR> FACILITY_TYPE_DESC<\/SPAN><\/SPAN><\/P><\/TD> Facility Type Description<\/SPAN><\/SPAN><\/P><\/TD> Text<\/SPAN><\/SPAN><\/P><\/TD> 30<\/SPAN><\/SPAN><\/P><\/TD> Description of the type of facility, e.g., Compressor Dehydrator<\/SPAN><\/SPAN><\/P><\/TD><\/TR> FACILITY_NAME<\/SPAN><\/SPAN><\/P><\/TD> Facility Name<\/SPAN><\/SPAN><\/P><\/TD> Text<\/SPAN><\/SPAN><\/P><\/TD> 58<\/SPAN><\/SPAN><\/P><\/TD> Combination of the operator abbreviation, field name and grid location (DLS/NTS)<\/SPAN><\/SPAN><\/P><\/TD><\/TR> APPLICATION_NUMBER<\/SPAN><\/SPAN><\/P><\/TD> Application Number<\/SPAN><\/SPAN><\/P><\/TD> Long<\/SPAN><\/SPAN><\/P><\/TD> 10<\/SPAN><\/SPAN><\/P><\/TD> System-generated nine-digit number assigned to the application for all activities and land being applied for within an application<\/SPAN><\/SPAN><\/P><\/TD><\/TR> APPLICATION_TYPE<\/SPAN><\/SPAN><\/P><\/TD> Application Type<\/SPAN><\/SPAN><\/P><\/TD> Text<\/SPAN><\/SPAN><\/P><\/TD> 40<\/SPAN><\/SPAN><\/P><\/TD> Type of application submitted by the applicant to the Regulator's Application Management System<\/SPAN><\/SPAN><\/P><\/TD><\/TR> APPLICATION_STATUS<\/SPAN><\/SPAN><\/P><\/TD> Application Status<\/SPAN><\/SPAN><\/P><\/TD> Text<\/SPAN><\/SPAN><\/P><\/TD> 40<\/SPAN><\/SPAN><\/P><\/TD> Status of the application prior to Approval<\/SPAN><\/SPAN><\/P><\/TD><\/TR> APPLICATION_SUBMITTED_DATE<\/SPAN><\/SPAN><\/P><\/TD> Application Submitted Date<\/SPAN><\/SPAN><\/P><\/TD> Date<\/SPAN><\/SPAN><\/P><\/TD> Date the application is submitted to the Regulator by the applicant<\/SPAN><\/SPAN><\/P><\/TD><\/TR> REVISION_NUMBER<\/SPAN><\/SPAN><\/P><\/TD> Revision Number<\/SPAN><\/SPAN><\/P><\/TD> Short<\/SPAN><\/SPAN><\/P><\/TD> 5<\/SPAN><\/SPAN><\/P><\/TD> Number of times the application has been altered prior to approval<\/SPAN><\/SPAN><\/P><\/TD><\/TR> APPLICATION_DETERMINATION_NUM<\/SPAN><\/SPAN><\/P><\/TD> Application Determination Number<\/SPAN><\/SPAN><\/P><\/TD> Text<\/SPAN><\/SPAN><\/P><\/TD> 9<\/SPAN><\/SPAN><\/P><\/TD> Upon decision, all activities permissioned will be <\/SPAN><\/SPAN><\/P> referenced under an application determination number<\/SPAN><\/SPAN><\/P><\/TD><\/TR> PROPONENT<\/SPAN><\/SPAN><\/P><\/TD> Proponent<\/SPAN><\/SPAN><\/P><\/TD> Text<\/SPAN><\/SPAN><\/P><\/TD> 60<\/SPAN><\/SPAN><\/P><\/TD> Organization name of the oil and gas operator<\/SPAN><\/SPAN><\/P><\/TD><\/TR> AUTHORITY_TYPE<\/SPAN><\/SPAN><\/P><\/TD> Authority Type<\/SPAN><\/SPAN><\/P><\/TD> Text<\/SPAN><\/SPAN><\/P><\/TD> 4<\/SPAN><\/SPAN><\/P><\/TD> Type of authorization issued by the Regulator. Authorizations are issued either under the Energy Resources Activities Act (ERAA) or the Canada Energy Regulator (CER)<\/SPAN><\/SPAN><\/P><\/TD><\/TR> DATA_SOURCE<\/SPAN><\/SPAN><\/P><\/TD> Data Source<\/SPAN><\/SPAN><\/P><\/TD> Text<\/SPAN><\/SPAN><\/P><\/TD> 5<\/SPAN><\/SPAN><\/P><\/TD> Data capture method used to collect the spatial application data submitted to the Regulator, i.e., GPSD (GPS-Differential), GPSND (GPS-Non Differential), ORTHO (Ortho Photography), CGWC (Coordinate Geometry With Control), SNK (Source Not Known)<\/SPAN><\/SPAN><\/P><\/TD><\/TR><\/TBODY><\/TABLE> Facility Type Codes/Descriptions<\/SPAN><\/SPAN><\/P> FACILITY_TYPE<\/SPAN><\/SPAN><\/P><\/TD> FACILITY_TYPE_DESC<\/SPAN><\/SPAN><\/P><\/TD><\/TR> AMM<\/SPAN><\/SPAN><\/P><\/TD> Ammonia Manufacturing<\/SPAN><\/SPAN><\/P><\/TD><\/TR> B<\/SPAN><\/SPAN><\/P><\/TD> Battery Site<\/SPAN><\/SPAN><\/P><\/TD><\/TR> B2<\/SPAN><\/SPAN><\/P><\/TD> Processing Battery<\/SPAN><\/SPAN><\/P><\/TD><\/TR> CAR<\/SPAN><\/SPAN><\/P><\/TD> Carbon Dioxide Storage<\/SPAN><\/SPAN><\/P><\/TD><\/TR> CD<\/SPAN><\/SPAN><\/P><\/TD> Compressor Dehydrator<\/SPAN><\/SPAN><\/P><\/TD><\/TR> CS<\/SPAN><\/SPAN><\/P><\/TD> Compressor Station<\/SPAN><\/SPAN><\/P><\/TD><\/TR> DS<\/SPAN><\/SPAN><\/P><\/TD> Disposal Station<\/SPAN><\/SPAN><\/P><\/TD><\/TR> GC<\/SPAN><\/SPAN><\/P><\/TD> Gas Conversion<\/SPAN><\/SPAN><\/P><\/TD><\/TR> GD<\/SPAN><\/SPAN><\/P><\/TD> Gas Dehydrator<\/SPAN><\/SPAN><\/P><\/TD><\/TR> GP<\/SPAN><\/SPAN><\/P><\/TD> Gas Processing Plant<\/SPAN><\/SPAN><\/P><\/TD><\/TR> HYD<\/SPAN><\/SPAN><\/P><\/TD> Hydrogen Manufacturing<\/SPAN><\/SPAN><\/P><\/TD><\/TR> IS<\/SPAN><\/SPAN><\/P><\/TD> Injection Station<\/SPAN><\/SPAN><\/P><\/TD><\/TR> LNG<\/SPAN><\/SPAN><\/P><\/TD> LNG Facility<\/SPAN><\/SPAN><\/P><\/TD><\/TR> MET<\/SPAN><\/SPAN><\/P><\/TD> Methanol Manufacturing<\/SPAN><\/SPAN><\/P><\/TD><\/TR> NGL<\/SPAN><\/SPAN><\/P><\/TD> NGL Fractionation Facility<\/SPAN><\/SPAN><\/P><\/TD><\/TR> OM<\/SPAN><\/SPAN><\/P><\/TD> Oil Sales Meter<\/SPAN><\/SPAN><\/P><\/TD><\/TR> OTH<\/SPAN><\/SPAN><\/P><\/TD> Other Facilities<\/SPAN><\/SPAN><\/P><\/TD><\/TR> PDE<\/SPAN><\/SPAN><\/P><\/TD> Shared Facilities<\/SPAN><\/SPAN><\/P><\/TD><\/TR> PE<\/SPAN><\/SPAN><\/P><\/TD> Pipeline Equipment<\/SPAN><\/SPAN><\/P><\/TD><\/TR> PG<\/SPAN><\/SPAN><\/P><\/TD> Pipeline Gathering<\/SPAN><\/SPAN><\/P><\/TD><\/TR> PR<\/SPAN><\/SPAN><\/P><\/TD> Petroleum Refinery<\/SPAN><\/SPAN><\/P><\/TD><\/TR> PS<\/SPAN><\/SPAN><\/P><\/TD> Pump Station<\/SPAN><\/SPAN><\/P><\/TD><\/TR> SB<\/SPAN><\/SPAN><\/P><\/TD> Satellite Battery<\/SPAN><\/SPAN><\/P><\/TD><\/TR> SM<\/SPAN><\/SPAN><\/P><\/TD> Gas Sales Meter<\/SPAN><\/SPAN><\/P><\/TD><\/TR> TF<\/SPAN><\/SPAN><\/P><\/TD> Test Facility<\/SPAN><\/SPAN><\/P><\/TD><\/TR> TT<\/SPAN><\/SPAN><\/P><\/TD> Tank Terminal<\/SPAN><\/SPAN><\/P><\/TD><\/TR> WF<\/SPAN><\/SPAN><\/P><\/TD> Well Facility<\/SPAN><\/SPAN><\/P><\/TD><\/TR> WH<\/SPAN><\/SPAN><\/P><\/TD> Water Hub<\/SPAN><\/SPAN><\/P><\/TD><\/TR><\/TBODY><\/TABLE> Renewal Triggers and Service Levels<\/SPAN><\/SPAN><\/P> Nightly<\/SPAN><\/SPAN><\/P><\/LI><\/OL> <\/P><\/DIV><\/DIV><\/DIV>",
"summary": "The Facility Locations (Proposed) (EPM_FACILITY_PT) is the location of facilities that have been submitted to the BC Energy Regulator for review and approval.",
"title": "Facility Locations (Proposed)",
"tags": [
"Facility",
"EPM",
"Application",
"Proposed",
"BCER"
],
"type": "",
"typeKeywords": [],
"thumbnail": "",
"url": "",
"minScale": 5000000,
"maxScale": 5000,
"spatialReference": "",
"accessInformation": "BCER",
"licenseInfo": " This data is for representation purposes only. The BC Energy Regulator provides this data \"as is\" with the understanding that it is not guaranteed to be accurate, correct or complete and conclusions drawn from such information are the responsibility of the user. It carries no guarantee of any kind, express or implied.<\/SPAN><\/SPAN><\/P><\/TD> <\/TD> <\/TD><\/TR> <\/TD>